TeSys D – Star Delta Starter

9A to 150A, Compact Design, Reliable Motor Starting and Protection

Star-delta Contactor Assemblies

9A to 300A, Pre‑wired and Tested, Reliable Motor Starting Solution

TeSys D – Star Delta Starter

Reliable Motor Starting Solution | 9A to 150A | Compact & Efficient

The TeSys D Star-Delta Starter is a trusted solution for reducing high inrush current during motor startup. Designed for three-phase motors from 9A to 150A, it ensures smooth operation while protecting the motor and extending its lifespan.

With its compact footprint, proven reliability, and seamless integration, the TeSys D starter is ideal for industrial environments where durability and efficiency matter.

Key Features

  • Current Rating: 9A to 150A
  • Compact design for space-saving panel installation
  • Reduced mechanical stress on motors and connected equipment
  • Soft motor start by minimizing voltage drop and inrush current
  • Durable TeSys D contactors for consistent performance
  • Thermal overload relay for protection against overcurrent
  • Quick wiring and easy maintenance with modular construction
  • Conforms to IEC 60947-4-1 and relevant global standards

Applications

  • Industrial machinery
  • Pumps and compressors
  • HVAC systems
  • Conveyors and material handling systems
  • Manufacturing plants and utility setups
  • Agriculture and irrigation systems

What You Get

  • TeSys D Star-Delta starter assembly
  • Main, star, and delta contactors
  • Thermal overload relay (optional model dependent)
  • Pre-wired configuration for easy installation

Technical Specifications – Schneider TeSys D Star-Delta Starter

ParameterDetails
Product TypeStar-Delta Starter Assembly
BrandSchneider Electric
SeriesTeSys D
Rated Operational Current (Ie)9A to 150A
Rated Operational Voltage (Ue)690V AC max
Rated Control Supply Voltage (Us)24V / 110V / 220V / 380V AC (model-specific)
Frequency50/60 Hz
Contactors UsedTeSys D LC1D Series (Main, Star, Delta)
Overload RelayLRD Thermal Overload Relay (adjustable)
Starter TypeOpen / Panel Mount
MountingBase or DIN rail (as per model)
Control MethodManual or automatic star-delta transition
Protection ClassIP20 / IP54 (enclosed models)
Standards ComplianceIEC 60947-4-1, CE
Electrical LifeUp to 1 million operations (AC-3 duty)
Mechanical LifeUp to 10 million operations
WiringPre-wired for quick installation
Operating Temperature–5°C to +60°C
Storage Temperature–40°C to +85°C
Auxiliary Contacts1 NO + 1 NC (optional based on configuration)
Panel Size RequiredCompact layout for optimized space
CertificationsCE, RoHS, IEC

Siemens Star-Delta Contactor Assemblies

9A to 300A | Pre-Wired & Tested | Reliable Motor Starting Solution
Siemens Star-Delta Contactor Assemblies are engineered for efficient and reliable motor starting across a wide range of industrial applications. Designed to reduce high starting current and torque during motor startup, these assemblies come pre-wired, factory-tested, and ready for installation — saving time while ensuring dependable performance. Built with Siemens high-quality contactors and thermal relays, these assemblies provide a complete, compact, and cost-effective solution for star-delta motor starting up to 300A.

Key Features

  • Current Range: 9A to 300A
  • Factory Pre-Wired: Minimizes installation time and wiring errors
  • Heavy-Duty Siemens Contactors: Long service life with consistent switching performance
  • Thermal Overload Relay Compatibility: Motor protection against overcurrent
  • Compact Design: Space-saving layout ideal for control panels
  • DIN Rail or Base Mounting Options: Flexible installation in any panel design
  • Wiring Standards: Neatly arranged, numbered, and color-coded as per Siemens specifications
  • Compliance: IEC 60947-4-1 and other global standards

Benefits

  • Reduces Starting Current: Star-delta transition helps minimize voltage drops and prevent system disturbances
  • Increases Motor Life: Less mechanical and thermal stress during startup
  • Ready-to-Install: Saves time, labor, and costs with factory-tested reliability
  • Enhanced Safety: Reduced risk of wiring faults and better overload protection
  • Proven Siemens Reliability: Built to perform in demanding environments
  • Easy Maintenance: Modular and accessible design simplifies servicing

Applications

  • Pumps and Irrigation Systems – Smooth startup prevents water hammer and stress
  • Compressors and Chillers – Avoids pressure surges and overloads
  • Conveyor Systems – Prevents belt wear from sudden torque
  • Blowers and Fans – Reduces vibration and noise during startup
  • Mixers, Crushers & Heavy Machinery – Protects against torque-related mechanical stress
  • Industrial Automation Panels – For seamless integration in complex electrical setups
  • Agriculture, Utilities & Manufacturing – Trusted across sectors for consistent motor performance

Technical Specifications

ParameterDetails
Product TypeStar-Delta Contactor Assembly
BrandSiemens
Rated Operational Current (Ie)9A to 300A
Rated Voltage (Ue)415V AC, 50/60Hz
Insulation Voltage (Ui)Up to 690V AC
Control Voltage Options24V / 110V / 220V / 380V AC (model dependent)
Frequency50Hz / 60Hz
Contactor TypeSiemens 3RT Series (Main, Star, Delta)
Overload RelaySiemens 3RU Thermal Overload Relay (manual reset)
MountingPanel Base or DIN Rail (customizable per model)
ConfigurationPre-wired, tested and ready-to-install
Starter TypeOpen type or enclosed (on request)
Protection FunctionsOverload, phase failure, mechanical interlocking
Enclosure Protection (optional)IP20 (open), IP54/IP65 (on enclosed request)
Auxiliary Contacts1 NO + 1 NC (expandable)
Standards ComplianceIEC 60947-4-1, VDE, CE
Electrical LifeUp to 1 million operations (AC-3 duty)
Mechanical LifeUp to 10 million operations
Operating Temperature Range–5°C to +60°C
CertificationsCE, RoHS, ISO Certified Assembly